Concrete Cover — EN 1992
الـ cnom من الـ Exposure class خطوة بخطوة بالمراجع: الـ Structural class (Table 4.3N)، و cmin,dur (Table 4.4N)، و cmin,b، و Δcdev، والصب على الأرض، والـ Abrasion — ورتبة الخرسانة الاسترشادية من Annex E.
- EN 1992-1-1:2004 §4.4.1
- Table 4.3N
- Table 4.4N
- Annex E
الأداة بتساعدك — المهندس المسؤول هو اللي بيراجع ويعتمد.
Design working life
Bars in a bundle
Concrete cast against
Δcdev: 10 mm recommended (§4.4.1.3(1)); 5–10 mm with a quality assurance system that measures the cover; 0–10 mm with accurate measurement and rejection of non-conforming members (e.g. precast), §4.4.1.3(3).
Nominal covercnom = 35mm
- Structural classS4
- cmin25 mm
- cmin,dur25 mm
- cmin,b16 mm
- Exposure class XC3 (Table 4.1). Structural class S4 (Table 4.3N): S4 for a design working life of 50 years (Table 4.3N, note).
- cmin,dur = 25 mm (Table 4.4N, reinforcing steel, S4, XC3)
- cmin,b = φ = 16 mm (Table 4.2)
- cmin = max(cmin,b; cmin,dur + Δcdur,γ − Δcdur,st − Δcdur,add; 10 mm) = max(16; 25; 10) = 25 mm (eq. 4.2, Δ terms = 0)
- cnom = cmin + Δcdev = 25 + 10 = 35 mm (eq. 4.1, §4.4.1.3)
Every exposure class — same settings
| Class | S | cmin,dur | cnom | Annex E min. |
|---|---|---|---|---|
| X0 | S3 | 10 | 26 | C12/15 |
| XC1 | S3 | 10 | 26 | C20/25 |
| XC2 | S4 | 25 | 35 | C25/30 |
| XC3 | S4 | 25 | 35 | C30/37 |
| XC4 | S4 | 30 | 40 | C30/37 |
| XD1 | S4 | 35 | 45 | C30/37 |
| XD2 | S4 | 40 | 50 | C30/37 |
| XD3 | S4 | 45 | 55 | C35/45 |
| XS1 | S4 | 35 | 45 | C30/37 |
| XS2 | S4 | 40 | 50 | C35/45 |
| XS3 | S4 | 45 | 55 | C35/45 |
Scope and references
- EN 1992-1-1:2004 §4.4.1 with the recommended values of the notes (no National Annex): Table 4.3N, Table 4.4N (reinforcing steel), Table 4.2, eq. (4.1)/(4.2) with Δcdur,γ = Δcdur,st = Δcdur,add = 0.
- Casting against prepared ground or soil: the minimum cover is at least 40 / 75 mm (§4.4.1.3(4)); Δcdev is added on top (on the safe side).
- Freeze–thaw (XF) and chemical attack (XA) do not change the cover in EN 1992-1-1 — they govern the concrete mix (EN 206).
- Not covered: prestressing tendons (Table 4.5N), stainless steel and added protection reductions, and the fire axis distance (EN 1992-1-2). Check your National Annex.
- The tool assists — the responsible engineer checks and approves.